B-0012_Sanitary Dryer L_Brochure_Rev2.0

MODEL OVERVIEW

L MODEL

Sanitary Dryer L150

Sanitary Dryer L300

Sanitary Dryer L400

Skidded System with Enclosure

Skidded System with Enclosure

Skidded System with Enclosure

Design

Applications (Process Lines - Sanitary Tube Sizes) Example Operating Condition

1.0" - 1.5"

2.0" - 3.0"

3.0" - 4.0"

60 CFM @ 300" W.C.

200 CFM @ 150" W.C.

350 CFM @ 80" W.C.

Max Flowrate

115 CFM

365 CFM

494 CFM

Max Pressure

337" W.C.

248" W.C.

104" W.C.

Max Temperature

220 °F

220 °F

220 °F

FEATURES

STANDARD

OPTIONAL

• UL, NEMA 4X control panel & components • CIP system integeration controls • 304ss enclosure / frame with access panels • Regenerative blower with VFD • Inlet and discharge silencers • Pressure relief valve • Pre-filter (99% efficient to 2 Micron) • 18 kW electric heater • Temperature transmitter • Pressure transmitter • Flowmeter

• Stand-alone controls (i.e., local PLC/HMI controlled) • Valves for CIP system integration (loose ship or installed on CIP) • Casters •  Humidity sensor (loose ship for humidity verification)

3