FBC-0001.5 Sanitary Components Catalog (2022)

COP System Accessories In-Tank Steam Mixer/Sparger

The steam mixer/sparger mixes steam with water in the tank to reduce noise and maximize heating capacity. Steam mixers/spargers are attached to either in-tank piping or a coupling that is mounted through the tank sidewall. Description Steam Inlet Connection Tank Connection Length Part #

0.5" MNPT

3.0" TC

8.69"

252795

316L stainless steel with one- piece ferruled assembly

0.75" MNPT

3.0" TC

9.44"

252790

1.0" MNPT

3.0" TC

8.13"

252792

NOTE: Sizing is determined by the line size & steam valve through which steam is delivered. NOTE: For older models with coupling welded into sidewall call a Sani-Matic sales representative.

Steam Regulator Valve The steam regulator automatically controls the temperature of your cleaning unit without the use of external power. With a vapor pressure thermal system, the steam regulator senses temperature change and positions the valve plug to regulate the heating or cooling medium to maintain a desired temperature.

Description

Connection Size

Part #

0.5"

020494 020495 020506

Brass with an FNPT connection type

0.75"

1.0"

NOTE: Maximum temperature setpoint is 170 °F.

Thermowell for Steam Regulator Thermal Bulb

Tri-Clamp x FNPT Fitting Thermowell

Description

Part #

Thermowell, 321 stainless steel tube, 9.25" overall length, 316 stainless steel fitting, 2.0" Tri-Clamp tank connection x 1.0" FNPT Thermowell connection

221907

117

FBC-0001.5

Powered by