CIPGuard ® The CIPGuard ® is an accessory available for monitoring proof of rotation for rotating spray devices. The CIPGuard can be installed centrally in the top of a tank head or tri-clamp port, and setup occurs via a connected PC to set rotation frequency and impact force parameters. When the unit is operating within set parameters, a digital PNP output signal can be sent to a connected PLC, confirming that the unit is within the rotation frequency and impact force parameters.
Image
Description Part #
Key Technical Data
Wetted Materials of Construction - PEEK
G 1 / 2 " Connection - use with welded sleeve
CIPGuard Sensor
053549
24V DC Supply Voltage
145 psi / 100 ° C max process temperature
Required for initial CIPGuard Sensor setup or parameter adjustment
PC Interface Cable, CIPGuard
USB connection for PC x M12 Adapter
053544
Free PC setup software available at http://www.awh.eu
Required for initial CIPGuard Sensor setup or parameter adjustment
CIPGuard Interface Cable, CIPGuard
053548
8 pin connection for CIPGuard Sensor x M12 Adapter
Wetter Materials of Construction - 316Lss
Hygienic Weld-In Sleeve, CIPGuard
G 1 / 2 " Connection - use with CIPGuard Sensor
N/A
053547
Can be welded directly onto vessel or onto tri-clamp cap
Angled M12 Connection
M12 Cable, Angled, 10 meters
052066
For use with CIPGuard Sensor
CIPGuard
Hygienic Weld Sleeve
Tank Wall
1 +VDC 2 Tx (only connectible via a prog. adapter) 3 GND 4 OUT/PNP 5 Rx (only connectible via a prog. adapter)
CIPGuard Installation Example
CIPGuard Wiring Diagram
109
HCS-0001.7
Powered by FlippingBook