Configurations
Right horizontal inlet with sight glass and differential pressure gauges shown.
NOTE: The strainer is drainable in the horizontal position, which requires draining both the inlet and outlet. For vertical or angled installation, the strainer is drainable out of the outlet when installed within 45° and 95° from horizontal.
Dimensional Information
Inlet/Outlet Size
Body Diameter
Available Configurations
A
B
C
D
1.5" TC x 1.5" TC
4"
20 3 /
4 " 4
1 /
8 "
24
7 /
16 "
1
1 /
4 "
LH, RH
20 1 /
2 " 4
3 /
8 "
24
7 /
16 "
1"
LH, RH, LB, RB
2.0" TC x 2.0" TC
4"
20 1 /
4 " 4
3 /
8 "
24
7 /
16 "
3 /
4 "
LH, RH, LB, RB
2.5" TC x 2.5" TC
4"
4 3 /
8 "
24
7 /
16 "
1 /
2 "
LH, RH, LB, RB
3.0" TC x 3.0" TC
4"
20"
NOTE: Lead times for LH and RB configurations are longer than RH and LB configurations.
Cv Values & Pressure Drops for Hygienic ALB Strainers Cv values are for the strainer when free of particulate loading. Cv values applicable for all perforation sizes, with or without mesh overlays (these variables have minimal impact to Cv values).
Cv Values
Cv values are for water, using the equation below:
Connection Size
Cv
1.5"
39 64
(
q = flow rate (gpm) SG = specific gravity (~1.0 for water) ∆P = pressure drop (psi)
SG ∆P
0.5
q
2.0" 2.5" 3.0"
Cv =
74
89
Hygienic ALB Strainer Pressure Drop
Flow Rate (gpm)
155
HCS-0001.7