HCS_0001_Hygienic Component Solutions Catalog_Rev8.0 (2025)

Configurations

Right horizontal inlet with sight glass and differential pressure gauges shown.

NOTE: The strainer is drainable in the horizontal position, which requires draining both the inlet and outlet. For vertical or angled installation, the strainer is drainable out of the outlet when installed within 45° and 95° from horizontal.

Dimensional Information

Body Diameter

Available Configurations

Inlet/Outlet Size

A B

C

D

1.5" TC x 1.5" TC

4"

20 3 /

4 " 4

1 /

8 "

24

7 /

16 "

1

1 /

4 "

LH, RH

20 1 /

2 " 4

3 /

8 "

24

7 /

16 "

1"

LH, RH, LB, RB

2.0" TC x 2.0" TC

4"

20 1 /

4 " 4

3 /

8 "

24

7 /

16 "

3 /

4 "

LH, RH, LB, RB

2.5" TC x 2.5" TC

4"

4 3 /

8 "

24

7 /

16 "

1 /

2 "

LH, RH, LB, RB

3.0" TC x 3.0" TC

4"

20"

NOTE: Lead times for LH and RB configurations are longer than RH and LB configurations.

Cv Values & Pressure Drops for High Purity ALB Strainers Cv values are for the strainer when free of particulate loading. Cv values applicable for all perforation sizes, with or without mesh overlays (these variables have minimal impact to Cv values).

Cv Values

Cv values are for water, using the equation below:

Connection Size

Cv

(

1.5"

39 64

q = flow rate (gpm) SG = specific gravity (~1.0 for water) ∆P = pressure drop (psi)

SG ∆P

0.5

q

Cv =

2.0" 2.5" 3.0"

74

89

High Purity ALB Strainer Pressure Drop

Flow Rate (gpm)

161

HCS-0001.8

Powered by