Angle-Line Basket Strainer Options The Drain / Sample Port helps operators drain strainers before removing the element for cleaning. Air relief sample valves are recommended for the Drain / Sample Port option. Differential Pressure ports allow operators to compare the pressure upstream and downstream of the element to help determine when to service the strainer.
Drain / Sample Port
Dual Sight Glass
Differential Pressure Connections with Pressure Gauges
Strainer sight glasses provide visual access to particulate buildup levels.
Cv Values & Pressure Drops for ALB Strainers Cv values or the provided pressure drop tables can be used to estimate the pressure drop across a strainer at a given flow rate. Cv values are for water at 70 °F. Contact Sani-Matic for inquiries on pressure drops for fluids with other viscosities.
Cv Values
Body Length
Connection Size
Cv
1.5"
44
2.0"
60
LONG (36")
2.5"
70
3.0"
75
4.0"
70
1.5"
45
2.0"
60
SHORT (20 ¾ ")
2.5"
70
3.0"
74
4.0"
70
NOTE: Cv values and charted pressure drops can be used for perforated, wedgewire, and perforated with mesh overlays or filter tubes. The clean pressure drop is minimally impacted by the element configuration in most cases. For worst-case calculations, add 20% to the calculated pressure drop.
Angle-Line Basket Strainer Pressure Drop: 4.0" Body, Standard Flow, LONG Body (36")
Angle-Line Basket Strainer Pressure Drop: 4.0" Body, Standard Flow, SHORT Body (20 ¾")
46
sanimatic.com
Powered by FlippingBook