HCS_0001_Hygienic Component Solutions Catalog_Rev8.0 (2025)

QUICK TIPS Are filter bags 3-A authorized?

Sani-Matic perforated element basket strainers are authorized to 3-A standard 42 In-Line Strainers. This standard covers metal strainers only. Using a filter bag does not negate the 3-A rating, however, our filters are not explicitly authorized under 3-A standard 10 Filters using Single Service Filter Media. When there is a heavy soil load, how can we remove the strainer element? An overhead crane may be needed to remove strainers containing heavy soil. Why is the standard sample / air relief vent valve important? The sample / air relief vent valve is used to relieve line pressure prior to opening the basket strainer cover for safety. GOOD TO KNOW • Material: Cast and heavy gauge 316Lss • Pressure Rating: 125 psi max @ 300 ° F (liquid service only) • ID Finish: 32 µin Ra (Strainer Body and Perforated Elements). Wedgewire elements have bead blasted finish. • SHORT Body Length Approximate Weight: 110 lbs. • LONG Body Length Approximate Weight: 130 lbs. • A complete assembly includes a strainer body, element, cover O-Ring, element O-Ring, sample valve, and vent valve clamp & gasket. • Each of the basket strainers manufactured is pressure tested using a hydrostatic test for quality assurance. • For wedgewire element sizing, it is recommended that the slot size is 30-50% smaller than the particle size to increase capture efficiency (e.g., to capture a 0.010" particle, use 0.005" or 0.007" wedgewire).

8" Body Size

8" Body Size

7"

SHORT Body Length Surface Area: 1.6 ft 2

LONG Body Length Surface Area: 3.7 ft 2 7"

70

sanimatic.com

Powered by