HCS_0001_Hygienic Component Solutions Catalog_Rev7.0 (2024)

QUICK TIPS Are filter bags 3-A authorized? While filter bags can be used with perforated elements for finer straining applications, they are not authorized to carry a 3-A symbol. Note: Filter bags require clamp ring and locking latch which are sold separately. When there is a heavy soil load, how can we remove the strainer element? An overhead crane may be needed to remove strainers containing heavy soil. Why is the standard sample / air relief valve important? The sample / air relief vent valve is used to relieve line pressure prior to opening the basket strainer cover for safety. GOOD TO KNOW • Material: Cast and heavy gauge 316Lss • Pressure Rating: 125 psi max @ 300 ° F (liquid service only) • Sanitary ID Finish: 32 µin Ra • Short Body Length Approximate Weight: 110 lbs. • Long Body Length Approximate Weight: 130 lbs. • A complete assembly includes a strainer body, element, cover O-ring, element O-ring, sample valve, and vent valve clamp & gasket. • Each of the basket strainers manufactured is pressure tested using a hydrostatic test for quality assurance.

8" Body Size

8" Body Size

37" Inlet-to- Outlet

22" Inlet-to- Outlet

7"

Short Body Length Surface Area: 1.6 ft 2

Long Body Length Surface Area: 3.7 ft 2 7"

70

sanimatic.com

Powered by