TD-0003_SaniCab® P_Technical Datasheet_Rev5.0

10.8 Chemical Control The Wash Conductivity Control option allows any chemical wash phase of the cleaning cycle to be controlled, monitored and alarmed with conductivity This allows for higher control of wash cycle chemical concentration The option adds the following components to the system: • Recirculation System − One (1) Toroidal conductivity sensor with 0-100 mS/cm range • Control System − One (1) Conductivity analyzer – single channel with a 4-20 mA output (mounted in the face of the control panel)

NOTE: • The Wash Conductivity Control option is required when selecting the 2-Pen Chart Recorder, Temperature & Conductivity Recording reporting option • Conductivity control is used for chemicals that can register a controllable conductivity value (eg, caustic, acids) Chemicals or conditions that are unable to register and control a conductivity value (eg, sanitizers, low conductivity acids used with high conductivity water) will use timed chemical injection

10.9 Controls The Allen-Bradley CompactLogix 5380 Controller option replaces the standard Allen-Bradley CompactLogix 5370 Controller and its I/O modules with an Allen-Bradley Bulletin 5069 CompactLogix 5380 Controller and corresponding I/O modules 10.10 Reporting Several reporting options are available for recording the critical cleaning cycle parameters of the SaniCab P: • 1-Pen Chart Recorder, Temperature Recording • 2-Pen Chart Recorder, Temperature & Conductivity Recording • SaniTrend ® Local • SaniTrend ® Cloud CR Essentials • SaniTrend ® Cloud CR Insights Chart recorders utilize circular paper charts to record selected cleaning parameters of the SaniCab P over a 24-hour period • 1-Pen Chart Recorder, Temperature Recording − A 1-Pen chart recorder for recording temperature is mounted to the system • 2-Pen Chart Recorder, Temperature & Conductivity Recording − A 2-Pen chart recorder for recording temperature and conductivity is mounted to the system

NOTE: • The 1-Pen Chart Recorder, Temperature Recording option is not available with the No Recirculated Heating option • The 2-Pen Chart Recorder, Temperature & Conductivity Recording is not available with the No Recirculated Heating option and requires the Wash Conductivity Control option

sanimatic.com 18

TD-0003.5

Powered by