TD-0003_SaniCab® P_Technical Datasheet_Rev5.0

Model Number Key

5 7 6 8 10 11 1213 1415161718 19 Example Model #: P335-110EAS-TM1-213S4-21M110C 9

Chamber Model P335 30" W x 35" D x 65" H P365 30" W x 73" D x 65" H P565 56" W x 71" D x 54" H Wetted Materials / Surface Finish 1

1–4

1

3 2 4

20 21 22 23 24 25 C

5

304 Stainless Steel & 32 µin Ra (Standard)

System Configuration 1

6

Right Handed (Standard)

2

Left Handed

Dryer System 0

7

No Dryer System (Standard)

1

Dryer System - Electric

Recirculated Heating S

8

In-Tank Steam Sparger (Standard)

X

Heat Exchanger - Steam

E

Electric Heater to Maintain Temperature

N

No Recirculated Heating

Pump Type A

9

Ampco (Standard)

W Waukesha F Fristam L Alfa Laval

Motor Type T

10

TEFC (Standard) W Washdown Duty S Supply Pressure Monitoring G

Stainless Steel Washdown

11

Pressure Gauge (Standard)

T

Pressure Transmitter

Supply Flow Monitoring N Flow Switch M Flow Meter S

12

No Flow Monitoring (Standard)

Chemical Control 0

13

Timed Chemical Injection (Standard)

1

Wash Conductivity Control

Controls 2

14

Allen-Bradley ® CompactLogix™ 5370 Controller (Standard)

3

Allen-Bradley CompactLogix 5380 Controller

HMI Display 1 Reporting 0

15

Allen-Bradley PanelView™ Plus 7 - 7" Operator Terminal (Standard)

16

No Reporting (Standard)

1

1-Pen Chart Recorder, Temperature Recording

2

2-Pen Chart Recorder, Temperature & Conductivity Recording

L

SaniTrend ® Local

E

SaniTrend ® Cloud CR Essentials

C

SaniTrend ® Cloud CR Insights

Conduit P

17

PVC Conduit (Standard)

S

Stainless Steel Conduit

Electrical Utility 4 Water Addition 0

18

460V AC, 3PH, 60 Hz (Standard)

19

Dual Water Ports (Standard)

1

Dual Water Ports with (1) Pneumatic Valve

2

Dual Water Ports with (2) Pneumatic Valves

Chemical Addition 0

20

Triple Chemical Ports (Standard)

1

Triple Chemical Ports with (1) Chemical Delivery Skid

2

Triple Chemical Ports with (2) Chemical Delivery Skids

3

Triple Chemical Ports with (3) Chemical Delivery Skids

Chamber Straining M Manual Perforated Screen (Standard) C Automated Conveyorized Mesh Screen

21

Recirculated Straining 0

22

No Recirculated Straining (Standard)

1

Y-Strainer - Wedgewire Element

Distribution Zones 0

23

Chamber Rotary Sprays (Standard)

1

Chamber Rotary Sprays & Active Coupler

Options 0

24

No Options (Standard)

sanimatic.com 2

1

Sample Valve

2

VessaLite ® Chamber Light

3

Sample Valve & VesssaLite ® Chamber Light

Powered by