5. Physical Size & Layout The following is the approximate overall size of the equipment The standard system orientation is a right-handed configuration, with the HMI interface, controls, and main external components on the right when viewing the system from the load side

Table 2: System Size

System Dimensions

Open Door Depth and Cart Length - Clearance (in)

Open Door Depth - Door Swing (in)

Max System Width - W Max (in)

Max System Depth - D Max (in)

Chamber Model

System Weight (lbs)

W"

D"

H"

P335 P365 P565

50 48 100 50 86 102 76 84 89

90

54

41 41

96

1,750

97

91

134 149

2,600 2,300

121

89

67

Cabinet Washer

Rack/Transfer Cart

Plan View

Front View

NOTE: • The Right Handed system configuration, featuring some non-standard options, is shown in the above image • The "CLEARANCE" dimension includes the length of the chamber door and the associated rack positioned in front of the door • System dimensions and system weight listed are for standard options • System operating weight is dependent on the construction of the loaded rack • All selectable product options within the model key fit within the footprint shown except for the following: − Dryer System – Electric (See Section 10.2 Dryer System ) −  Heat Exchanger – Steam (See Section 10.3 Recirculated Heating )

−  Triple Chemical Ports with (1) Chemical Delivery Skid (See Section 10.13 Chemical Addition ) − Triple Chemical Ports with (2) Chemical Delivery Skids (See Section 10.13 Chemical Addition ) − Triple Chemical Ports with (3) Chemical Delivery Skids (See Section 10.13 Chemical Addition )