DM-0003_Angle Line Strainer IOM_Rev 2.0

Table 3: Maximum Recommended Flow and Pressure Drop – “Reverse Flow” Direction

Max. Recommended Flow (gpm)

Pressure Drop @ Max. Recommended Flow 1 (psi)

Max. Allowable Pressure Drop Across Element – Perf. / Wedgewire 2 (psi)

Connection Size

Body Size

1.5” 2.0” 2.5” 3.0” 4.0” 3.0” 4.0” 6.0”

4.0” 4.0” 4.0” 4.0” 4.0” 6.0” 6.0” 6.0”

55

2.2 1.9 2.0 3.4 7.5 1.7 4.8

20 / 50 20 / 50 20 / 50 20 / 50 20 / 50 20 / 50 20 / 50 20 / 50

105 165 245 430 245 510 840

10.0

1 For 70 °F Water. 2 Elements exposed to pressures above this may sustain damage.

Safety Precautions 1. Do not exceed temperature or pressure rating of strainer assembly. 2. Do not loosen or remove any clamps while the strainer is under pressure. 3. Lockout supply pump(s) and other equipment in-line with the strainer during cleaning to prevent accidental operation when strainer is open. 4. Use protective gloves when removing strainer element and clearing debris from element. 5. Use only Sani-Matic replacement parts.

DM-0003_Angle Line Strainer IOM_Rev 2.0

2 of 6