Troubleshooting Table 4: Troubleshooting Problems
Solutions
1. Damaged element (replace). 2. Damaged housing (replace).
Element won’t fit into housing
1. If the debris is smaller than the perforation size, then a new element insert with smaller openings will be required. 2. A different straining element (perforated, wedgewire) may be required. 3. If present, the mesh overlay or filter tube may be damaged (replace). 4. The element may be damaged (replace). 5. The overall assembly may be loose – check retaining clip, O- ring, and end plug for fit up. 1. Strainer element size may be too small (use a larger element size). 2. The strainer is not cleaned out adequately during cleaning steps. 3. A dual strainer assembly may be required to switch between strainers and continue running while one strainer is being used (contact Sani-Matic for more information). 1. Tighten clamp. If leakage is still occurring replace the tri- clamp gasket. 2. Check the system temperature and pressure to ensure the pressure does not exceed the pressure ratings.
Particles are passing by the strainer.
Strainer is plugging frequently.
Leakage occurring at clamp connections