TD-0007_Hygienic ALB Strainer_Technical Datasheet_Rev1.1

Bio-Pharm

Technical Datasheet

Cleaning Confidence

Hygienic ALB Strainer Industry Leading Process Equipment Protection

Component and equipment protection is critical to keeping biopharmaceutical processes running - the Hygienic ALB Strainer protects these components during CIP and other process steps, allowing production to continue as-designed, safely, and uninterrupted.

Benefits

Hygienic ALB Strainer

• Tangential inlet to promote adequate cleaning velocities within body for elimination of dead leg concerns. • Unique patent pending strainer element cap design – reduces internal body scratching during servicing of strainer. • Standard 360° sight glass for particulate inspection without breaking process connection. • Ergonomic designs for strainer handle and element cap removal. • Particulates captured within basket element – catches all particulates on the interior for complete and easy removal. • Basket element end cap – allows for easy flushing of basket element. • Angle-line design allows for element removal without breaking process line components. • Tuf-Flex ® Tri-Clamp gaskets reduce “sticking” of seal when servicing strainer. • Materials of construction, surface finishes, certifications, and documentation package meeting industry standards. • Designed for low pressure drop. • Multiple inlet orientations and sizes to meet your process needs. • Eccentric fittings for full drainability in multiple installation orientations. • Optional pressure gauges or ports for monitoring particulate loading. • Optional interchangeable mesh underlays for finer straining.

Optimized Fluid Dynamics Design with CFD Modeling

Applications

• CIP Supply and Return Lines • Utility Supply Lines • Specific Equipment Protection • Buffer, Media Solution, Process Lines

(p sanimatic.com ()

Sani-Matic, Inc.

(p (p) 800-356-3300

(f)

TD-0007.1.1

Model Number Key

3 5 6 8 10 11 12 13 14 15 16 17 18 19 20 21 22 Example Model #: HALBS-A20RH-P250-0SF5S300 7 9 2 4

1

Component HALBS Hygienic ALB Strainer

1-5

Element Length A Connection Size 15 1.5" 20 2.0" 25 2.5" 30 3.0"

6

10.7" Element (0.7 ft 2 Area)

7, 8

Configuration RH Right Horizontal Inlet LH Left Horizontal Inlet RB Right Bottom Inlet LB Left Bottom Inlet Element Type / Size P093 Perforated / 0.09375" ( 3 / 32 ") P125 Perforated / 0.125" ( 1 / 8 ") P250 Perforated / 0.25" ( 1 / 4 ")

9, 10

11-14

Seal Kit

15

EPDM & Teflon Encapsulated Silicone O-Rings / Tuf-Flex Gaskets / FKM Sight Glass Seal (if applicable) EPDM & Teflon Encapsulated SIlicone O-Rings / EPDM Gaskets / FKM Sight Glass Seal (if applicable)

0

1

FInish / Polish SF5 20 µin Ra / Electropolish

16-18

Option 1 S

19

Sight Glass (Standard)

0

No Sight Glass

Option 2 0

20

None (Standard)

1

Differential Pressure Connections (Capped Ports)

2 3 4

Differential Pressure Connections with Pressure Gauges (0-30 psig) Differential Pressure Connections with Pressure Gauges (0-60 psig) Differential Pressure Connections with Pressure Gauges (0-100 psig)

Option 3 0

21

None (Standard)

V

Relief / Sample Valve

Option 4 0

22

None (Standard)

(p sanimatic.com (f)

Sani-Matic, Inc.

(p (p) 800-356-3300

(f)

TD-0007.1.1

Key Technical Data

Documentation Package

•  Temperature & Pressure Rating: 200 psi @ 70 °F / 125 psi @ 200 °F • Weight: 21-25 lbs (dependent on options chosen) • Max Pressure Drop Rating (Across Strainer Element): 40 psi •  Wetted Materials - Strainer Body and Element: 316Lss - Element Retainer O-ring: Teflon TM Encapsulated Silicone - Element End Cap O-ring: EPDM - Tri-Clamp Gaskets: Tuf-Flex ® PTFE/EPDM - Sight Glass Seals: FKM - Mesh Underlays (Optional) : 316Lss - Relief / Sample Valve (Optional): Teflon Seat / Viton Elastomers • Differential Pressure Connections (Optional): 2.0” TC •  Relief / Sample Valve (Optional): Welded to strainer element cap with 10mm hose barb connection outlet

• MTRs • Surface Finish Certification • UPS Class VI Certifications • Electropolish Certification • Passivation Certification • Weld & Heat Map • Weld Log • As-Built Drawings • Hydrostatic Test (Optional)

Strainer Element Assembly

Dimensional Information

Inlet/Outlet Size

Available Configurations

Body Dia.

A

B

C

D

1.5" TC x 1.5" TC

4" 4" 4" 4"

20 3 / 4 " 20 1 / 2 " 20 1 / 4 "

4 1 / 8 "

24 7 / 16 " 24 7 / 16 " 24 7 / 16 " 24 7 / 16 "

1 1 / 4 "

LH, RH

2.0" TC x 2.0" TC 2.5" TC x 2.5" TC 3.0" TC x 3.0" TC

4 3 / 8 " 4 3 / 8 " 4 3 / 8 "

1"

LH, RH, LB, RB LH, RH, LB, RB LH, RH, LB, RB

3 / 4 "

20"

1 / 2 "

NOTE: Lead times for LH and RB configurations are longer than RH and LB configurations.

NOTE: The strainer is drainable in the horizontal position, which requires draining both out the inlet and outlet. For vertical or angled installation, the strainer is drainable out of the outlet when installed between 45 ° and 90 ° from horizontal.

(p sanimatic.com (f)

Sani-Matic, Inc.

(p (p) 800-356-3300

(f)

TD-0007.1.1

Mesh Underlays

Micron (Approx. Equiv.)

Opening Width in Inches (Approx. Equiv.)

Mesh Size

20 40 60

850 425

0.0340"

0.0150"

250

0.0092" 0.0060"

100

150

60 Mesh Underlay

Cv Information

Connection Size

Cv

• Cv values are for the strainer when free of particulate loading. • C v values applicable for all perforation sizes, with or without mesh overlays

1.5"

39 64

2.0" 2.5" 3.0"

(these variables have minimal impact to Cv values). • Cv values are for water, using the equation below:

74

89

Hygienic ALB Strainer Pressure Drop

(

SG ∆P

0.5

q

Cv =

q = flow rate (gpm) SG = specific gravity (~1.0 for water) ∆P = pressure drop (psi)

Flow Rate (gpm)

(p sanimatic.com (f)

Sani-Matic, Inc.

(p (p) 800-356-3300

(f)

TD-0007.1.1

Page 1 Page 2 Page 3 Page 4

www.sanimatic.com

Powered by