TANKO® SF_IOM_Rev0

Spate cleaner TANKO-SF

5.2.1 Interfaces

A Actuator / Energy Supply Media connection [MC] (connection of the downpipe [DP] to the device) B Device / Container Process connection [PC] (connection of the downpipe [DP] to the container) C Space for Movement / Installation Space Cleaning head with spray openings for the cleaning agent

B

A

C

Picture 5.2-1: Device Interfaces

Assignment of the Connections

The correct downpipe dimensions are important in order to achieve the volumetric flows specified in these instructions.

The Clipon and Weldon versions of the TANKO-SF are intended for connection to the following downpipes:

Connection for Pipe acc. to DIN 11866

Article No.

Downpipe

Clipon Series A (DIN)

665 F4 41A1 6230

Ø 19.0 x 1.5

Clipon Series B (ISO)

665 F4 77A1 6230

Ø 21.3 x 1.6

Clipon Series C (ASME)

665 F4 90A1 6230

Ø 19.05 x 1.65

Weldon Series A (DIN)

665 F4 42A1 6630

Ø 23.0 x 1.5

Weldon Series C (ASME)

665 F4 91A1 6630

Ø 25.4 x 1.65

Table 5.2-1: Assignment of the Connections

5 Installation

Translation of the original Operating / Installation Instructions 2016/09 Rev.1 25/63

Powered by