TANKO® SF_IOM_Rev0

Spate cleaner TANKO-SF

NOTE

Operation of the device with steam or gases! The conveyance of steam or gases through the device (e.g. for sterilization) leads to extremely high rotation speed on the part of the cleaning head. Severe wearing on the bearing surfaces or destruction of the device could be the result.

 Do NOT channel steam or gases through the device into the container.

 Carry out sterilization of the device only through the container, i.e. apply steam or gases to the container.

The safety systems and safety notes in the operating instructions for the higher-level plant/machine must be adhered to. The area around the plant/machine and the operator work stations at the plant/machine must be keep free of objects during operation so that unobstructed access is possible at all times. In order to ensure fault-free operation, the device must be treated with care at all times.

When operating the device, adhere to the following additional instructions:

WARNING Persons in the container. A person may be struck by the jets from the cleaning head!

There is a risk of death or severe physical injuries.

 DO NOT start cleaning operation while there are persons in the container.

 NEVER direct the cleaning jet at persons.

WARNING Incorrect operation of the device!

There is a risk of death or severe physical injuries.

 Only operate the device when it is in perfect condition.

 Allow only experts to operate the device.

 Do not operate the device unless it is installed inside an enclosed container.

 Drain and depressurize the container being cleaned.

 Securely close all of the openings on the container (e.g. inspection openings).

 When operating the device, adhere to the switch-on and switch-off procedures (see sections 6.3 Switch-on Procedure and 7.2 Switch-off Procedure ).

 There is no need for the device to be run in.

 The following operating states of the device are NOT permitted:

– Operation of the device without cleaning agent.

– Immerse the device in the product of the production process.

– Operation of the device outside the permitted parameters (see section 3.3 Technical Data ).

 Immediately stop operation in the event of leaks outside the container.

 Refrain from any type of work which compromises the safe and reliable function of the device.

34/63 Translation of the original Operating / Installation Instructions 2016/09 Rev.1

6 Commissioning

Powered by