TANKO® SF_IOM_Rev0

Spate cleaner TANKO-SF

7.4.5 Notes on Cleaning

It is recommended for the device to be cleaned during maintenance.

Comply with the following safety notes prior to cleaning.

WARNING

Hazard from corrosive or aggressive cleaning agents! There is a risk of death or severe physical injuries.

 Adhere to the regulations and specifications in the safety data sheets for the cleaning agents (e.g. vapors or hazardous substances).

 Use personal protective equipment (e.g. protective gloves, safety shoes, safety goggles).

 Avoid excessive concentration of the cleaning agent.

 Use only clean and chlorine-free water as a diluting agent.

 Flush the device with plenty of clean water after cleaning.

 Store cleaning agent in accordance with the applicable safety guidelines.

NOTE

Risk of damage to the device during cleaning! The use of incorrect cleaning agent or sharp objects can damage the device. The functional safety and reliability of the device may be compromised.

 The cleaning agents must be approved for all materials of the device (e.g. seals, bushings).

 Do not use sharp objects (e.g. knives) or tools.

NOTE

Formation of hydrochloric acid when cleaning the device! No dry adhesions or deposits of cleaning agent should be left behind in the device. This could cause the cleaning agent to salt out or form crusts. If the cleaning agent contains volatile solvents containing chloride, then hydrochloric acid could arise when rinsing with clear water. The functional safety and reliability of the device may be compromised.  DO NOT rinse with clear water if the cleaning agent includes volatile solvents containing chloride.

The following must be observed when blowing out the device with air:

– fix the head in place in such a way that it cannot rotate while being blown out

– use filtered, oil-free compressed air

– Time of the dry-blowing 5 – 10 min (longer is technically possible but not necessary under normal circumstances)

46/63 Translation of the original Operating / Installation Instructions 2016/09 Rev.1

7 Maintenance

Powered by