Spate cleaner TANKO-SF

8.2 Faults and Remedial Action

Fault

Cause

Remedy

Effectiveness of the cleaning process is inadequate

Pressure for the cleaning fluid is insufficient or no cleaning fluid pressure.

Check the pressure of the cleaning agent

Check the filter and clean it if necessary

Check the outlet opening on the device and clean it if necessary Check the pressure of the cleaning agent and reduce pressure if necessary

Pressure of the cleaning agent too high, cleaning agent turns into mist

Spray head does not rotate

Holes blocked

Clean holes

Holes deformed

Replace the device

Sliding surfaces soiled

Clean the device

Device is worn

Replace the device

Table 8.2-1: Operating Faults – Cause and Remedy

If the specified measures are NOT successful, please contact AWH.

In the event of return shipment (e.g. repair / servicing / return), a hazardous substance declaration must be enclosed with the device in accordance with the Hazardous Substance Directive (GefStoffV). Request the form for the hazardous substance declaration from AWH.