Interface B

The connection to the container must be designed to that it is compatible with the process connection [PC] for the downpipe [DP]. The process connection [PC] must be fastened permanently and leak-tight to the connection on the container (e.g. screwed or clamping) and secured to prevent it from coming loose. WARNING NON-threaded process connections [PC], e.g. detachable connections with a clamp or catch design, may come loose unintentionally!

There is a risk of fluids getting in or spraying out (carryover of zones).

 Process connections [PC] with a clamp or catch design must:

– be self-locking (e.g. mechanical locking with safety lock) or – provided with an additional securing mechanism to prevent them from coming loose accidentally.

The operating company is solely responsible for fastening the device to the container.

Interface C

NOTE Excessively small installation openings on the container or components (e.g. agitators) in the container! Nozzles collide during installation!

Damage to the device. The nozzle carrier may come loose.

 The nozzles must NOT collide!

1. Check the following before inserting the device into the container:

– The minimum dimension for the installation opening (see section 3.3 Technical Data ),

– Presence of interfering contours on surrounding components in the container and

– That the nozzle carrier with nozzles is firmly in place on the cleaning head.

2. Insert the device into the container through the installation opening with the utmost care.

NOTE “ Installation opening - stationary device ”  Before installation, align the position of the nozzles if necessary by rotating the cleaning head/nozzles.  Fasten the cleaning head/device inside the container. – Provided that proper installation and assembly/removal of the cleaning head/device inside the container is assured and – The diameter of the installation opening on the container is at least 5 mm greater than the outer diameter of the downpipe [DP]. NOTE “ Installation opening - mobile device ” Smaller installation openings on the container “ for mobile use ” of the device, as specified in section 3.3 Technical Data , are permitted only:  If the cleaning head fits through the installation opening with the nozzles in any position during installation and removal of the device (e.g. by using shorter nozzles) and  a safety clearance of at least 5 mm all around the device between the device and the installation opening is ensured.