8.2 Faults and Remedial Action

Fault

Cause

Remedy

Cleaning head and/or nozzle carrier not rotating or rotating unevenly.

– There is no media pressure on the device. – Pressure of the cleaning agent too low. – Pressure of the cleaning agent too high. – Excessive friction due to wear on the bushings and/or bearings. – Actuator unit in the device damaged or contaminated with deposits or foreign objects. The teeth of the spur gears jam. – The cleaning head collides with installed components. – Nozzles are blocked mechanically by interfering contours. – Nozzle jet too close to surrounding components. Due to high media pressure (recoil).

– Open the shut-off valve for the medium. – Increase the pressure (adhere to the max. permitted pressure).

– Reduce the pressure.

– Check the bushings and/or bearings for wear, clean or replace them. – Clean the inside of the device and remove any foreign objects. Replace the spur gears.

– Eliminate the interfering contours.

– Check the position in the container. – Increase the distance to surrounding components.

– Filter or nozzles blocked.

– Clean the filter or nozzles.

Effectiveness of cleaning is inadequate.

– Nozzles soiled or blocked.

– Clean or replace the nozzles.

– Pressure of the cleaning agent too low.

– Increase the pressure (adhere to the max. permitted pressure).

– Volume flow rate too low.

– Increase the volume flow rate

– Filter blocked.

– Clean or replace the filter.

Jet pattern not ideal.

– No jet concentrators in the nozzles.

– Retrofit jet concentrators.

– Nozzles soiled.

– Clean the nozzles.

– Nozzles damaged.

– Replace the nozzles

Process or media connection leaking.

– Seal defective.

– Replace the seal.

– Connections have come loose.

– Check the tightening torque values of the screw connections.

Volume flow rate too high. – Increased leakage due to heavily worn bushings or bearings.

– Replace the bushings or bearings.

Table 8.2-1: Operating faults – cause and remedy

If the specified measures are NOT successful, please contact AWH.