TANKO® CP_IOM_Rev5

TANKO®-CP Jet Cleaner

3.2 General Function Description

The item numbers shown in brackets refer to the Picture 7.5-1: TANKO-CP2 design and the Picture 7.5-3: TANKO-CP3 design.

The cleaning agent enters the device at the connection cover (4, 5 for CP3) and flows into the inside of the device through the drilled holes in the inflow disk (1). The fluid arrives at the shaft (2) there and sets it into rotation. The fluid flows down on the outside of the shaft (2) and then through side holes in the shaft (2) into the inside of the shaft, and from there into the cleaning head (8, 9 for CP3). From there, the fluid passes through the spraying holes in the cleaning head and back out again. The cleaning head is connected to the shaft using a cotter pin (9, 10 on CP3). The rotation of the shaft is transferred onto the cleaning head directly by the cotter pin. The long drilled holes in the cleaning head ensure that the cleaning jet is concentrated in the optimum manner. The slow rotation and powerful impact of the cleaning jet removes even stubborn soiling from the container wall. The cleaning jet follows a linear path on the container wall. The spreading of the cleaning jet and the arrangement of the spray holes in the cleaning head ensure good cleaning. Leakages on the cleaning device and the drilled hole which points upwards on the spraying head are used for self-cleaning of the device.

Depending on the requirements, devices with different spraying angles are available.

Cleaning times:

– If the entry pressure is 3 - 12 bar (44 - 174 psi), the average rotary speed of the TANKO-CP is 2 - 30 rpm.

– Deviations of 10 - 15 % in the rotation speed are a feature of the design.

– With spontaneous pressure build-up, a run-in period of 2 – 4 minutes must be added to the cycle time. – The rotation speed of the cleaning head can be varied using a plug (10, 11 for CP3) in the middle of the inflow disk (1). As standard, the device is supplied without a plug screwed in. The plugs are provided loose with the device. – The device rotates at its slowest rotation speed. If you want the device to rotate faster, screw a plug with a hole into the central hole in the inflow disk. The smaller the hole in the plug, the faster the cleaning head turns. It turns fastest if the closed plug (without a hole) is used.

Reducing the hole diameter in the bypass plug also reduces the flow rate in the device.

– The time for one cleaning cycle depends on several factors, and must be defined individually by the operating company.

Sample applications for jet cleaner type TANKO-CP:

Tanks, silos, barrels, containers, pipes, dryers, centrifuges, agitators, vacuum tanks, spraying towers, container washing plants, fermenters, filters, mixing containers and horizontal dryers.

17/77

3 Construction and Function Translation of the original operating/installation instructions 2016/10

Powered by