5.2.2 Installation Position

1) Aligned vertically with the cleaning head pointing downwards (standard): The device is designed for vertical installation as the preferred position. This installation position means that the device can drain automatically. 2) Different installation position from the standard: A different installation position to the standard position means that the device may NOT always be able to drain automatically. The strain on the bearings is also increased.

Adhere to the following:

– The running performance may be compromised.

– The service life of the bearing elements may be shortened as a result of the increased strain.

– Maintenance intervals should be shortened if necessary (see section 7.4.1 Maintenance Intervals ).

5.2.3 Installing the Device

Clip-on connection (for TANKO-CP2 and TANKO-CP2S only)

4 Connection cover

11 Connection pin

12 Cotter pin

12

11

4

Picture 5.2-7: Clip-on connection

WARNING Risk of the device falling accidentally!

The device may strike personnel when falling.

There is a risk of severe physical injuries.

 Hold the device firmly when installing/removing it.

 There must be nobody beneath the device when installing/removing it.

NOTE Risk of dirt and foreign objects in the device!

Functional safety and reliability may be compromised.

 During assembly, make sure and check that there is no dirt or foreign objects in the device (e.g. small particles, sealing material).

1. Push the device with the connection cover (4) onto the pipe for the media supply.

2. Push the connection pin (11) through the connection cover (4) and the pipe for the media supply.

3. Secure the connection pin (11) with the cotter pin (12).

4. Make sure that the cotter pin (12) is installed properly.