8.2 Faults and Remedial Action

Fault

Cause

Remedy

The cleaning head does not rotate and/or no fluid is expelled.

Pressure for the cleaning fluid is insufficient or no cleaning fluid pressure. The strainer/filter or spray holes are blocked.

Set the pressure and volumetric flow rate to the standard values.

Clean the strainer and filter.

Remove the device and check for blocked spray holes or deposits. Check the volumetric flow rate of the device while the cleaning head is removed. Move the cleaning head by hand. In case of stiffness, internal damage may have been caused by a knock or blow. Replace faulty parts.

Spraying head does not rotate although enough cleaning fluid is flowing

The plain or running surfaces of the bearing have been damaged. Bushings and/or bearings are seizing.

Deposits or damage in the device

Check the bushings and/or bearings for wear, clean or replace them.

Table 8.2-1: Operating Faults – Cause and Remedy

If the specified measures are NOT successful, please contact AWH.

In the event of return shipment (e.g. repair / servicing / return), a hazardous substance declaration must be enclosed with the device in accordance with the Hazardous Substance Directive (GefStoffV). Request the form for the hazardous substance declaration from AWH.

69/77

8 Faults Translation of the original operating/installation instructions 2016/10