TANKO® MX_IOM_Rev0

Jet Cleaner TANKO-MX

B

A

C

C

Figure 5.2-2: Interfaces of the MX125 device

A Actuator / Energy Supply Media connection [MC] (connection of the downpipe [DP] to the device) B Device / Container Process connection [PC] (connection of the downpipe [DP] to the container) C Space for Movement / Installation Space Cleaning head with nozzles (space for orbital nozzle movement and outlet of cleaning agent) 5.2.2 Installation Position 1) Aligned vertically with the cleaning head pointing downwards (standard): The device is designed for vertical installation as the preferred position. This installation position means that the device can drain automatically. 2) Different installation position to the standard: A different installation position to the standard position means that the device may NOT always be able to drain automatically. The strain on the bearings is also increased. Adhere to the following: – The running performance may be compromised. – The service life of the bearing elements may be shortened as a result of the increased strain. – Shortening of maintenance intervals (see section 7.4.1 Maintenance Intervals ).

5 Installation

Translation of the original operating/installation instructions 2016/03

29 / 86