TANKO® MX_IOM_Rev0

Jet Cleaner TANKO-MX

Interface A The supply line connection must be configured to be compatible with the media connection [MC] of the device. The supply line for the cleaning agent has to be fastened permanently and leak-tight to the media connection [MC]. Threaded Connection NOTE Risk of damage to the device during installation. The fastening of a strap wrench to the housing is NOT a suitable measure for fastening the device to and removing the device from the pipe for the media supply. The threaded connection between the housing and the connection cover may become damaged as a result of excessive tightening torque. Maintenance and cleaning may become more difficult or even impossible.  Only use the wrench flat on the connection cover for screwing on and unscrewing the device on the pipe for the media supply (see Figure 5.2-3: Threaded connection installation ).

Figure 5.2-3: Threaded connection installation 1. Remove the screw cap/sealing plug from the media connection [MC]. 2. Screw the female thread in the connection cover (01) to the male thread on the connection line for media supply. NOTE If the tightening torque applied for the threaded connection between the connection cover and the pipe is excessive, there is a risk of damage to the thread.  The tightening torque values for the threaded connections between the connection cover and pipe depend on the material of the pipe for the media supply. 3. Tighten the threaded connection between the connection cover and the pipe using an open- ended wrench or adjustable pliers wrench, as shown in Figure 5.2-3: Threaded connection installation.

5 Installation

Translation of the original operating/installation instructions 2016/03

31 / 86

Powered by