19. NOTE Left-hand thread of the connection! Turning the incorrect direction can damage the threaded connection.
Make sure that the threaded connection is turned in the correct direction “ LH ” (left-hand). Unfasten the actuator unit assembly using an open-end wrench on the flats WAF 14 of the shaft of the spur gear (22). Unscrew the actuator unit assembly from the dome of the shaft-axle connection (24).
20. Remove the collar bushing (07) from the shaft-axle connection (24). 21. Remove the shaft-axle connection (24) from the vise.
22. Repeat the following steps in accordance with the number of nozzles (12). Fasten the nozzle carrier (27) in the vise. The nozzle (12) being unfastened faces upwards.
Unfasten the nozzle (12) and unscrew it from the nozzle carrier (27). Pull the jet concentrator (13) from the nozzle (12), e.g. with a set of pliers. Remove the nozzle carrier (27) from the vise.
7 Maintenance
Translation of the original operating/installation instructions 2016/03