TANKO® MX_IOM_Rev0

Jet Cleaner TANKO-MX

19. NOTE Left-hand thread of the connection! Turning the incorrect direction can damage the threaded connection.

 Make sure that the threaded connection is turned in the correct direction “ LH ” (left-hand).  Unfasten the actuator unit assembly using an open-end wrench on the flats WAF 14 of the shaft of the spur gear (22).  Unscrew the actuator unit assembly from the dome of the shaft-axle connection (24).

20. Remove the collar bushing (07) from the shaft-axle connection (24). 21. Remove the shaft-axle connection (24) from the vise.

22. Repeat the following steps in accordance with the number of nozzles (12).  Fasten the nozzle carrier (27) in the vise. The nozzle (12) being unfastened faces upwards.

 Unfasten the nozzle (12) and unscrew it from the nozzle carrier (27).  Pull the jet concentrator (13) from the nozzle (12), e.g. with a set of pliers.  Remove the nozzle carrier (27) from the vise.

7 Maintenance

Translation of the original operating/installation instructions 2016/03

57 / 86