Table 8: Steam Heating Data
Approx. Heatup Time 20 ° C to 80 ° C (min)
Chamber Model
Connection Size / Type (Steam Supply)
Connection Size / Type (Condensate Return)
Load (lbs / hr)
SP333 SP443 SP444
10 10 10
075" Flange 075" Flange 075" Flange
05" Flange 05" Flange 05" Flange
120
180 180
NOTE: • The standard design is sized for applications with 50 psi steam Installations where the plant supplied steam is in excess of 50 psi may require a pressure reducing valve (PRV) Unless otherwise specified, it is assumed that the PRV is customer supplied and/or installed by others
10.6 Supply Pressure Monitoring The Pressure Transmitter option replaces the pressure gauge in the circulation system with a diaphragm type pressure transmitter The pressure transmitter has 0-60 psi range and 4-20 mA output This option adds system monitoring and alarming capabilities for the supply pressure 10.7 Supply Flow Monitoring The Flow Meter option replaces the flow switch in the circulation system with a turbine flow meter The flow meter has 0-200 gpm range and 4-20 mA output This option adds system monitoring and alarming capabilities for the supply flow 10.8 Reporting The Report Ticket Printer option adds a thermal serial printer to the system The printer enables the system to provide a printed report containing the wash parameters of the cleaning cycle All report data is stored in a buffer that is flushed upon starting the next cleaning cycle The printer is mounted through the washer’s unload side service panel Additional controls include a 120V power transformer in the HV electrical enclosure and a 120V power receptacle mounted behind the service panel SaniTrend® Cloud Cleaning
Records (CR) Insights+ is an online data software that provides auto- mated, secure data acquisition and reporting of critical cleaning cycle information, along with system opera- tional efficiency insights Users, having
OEE Reports
Cleaning Cycle Report
a facility user login account, access SaniTrend Cloud via a web browser The Insights+ edition of SaniTrend Cloud is 21 CFR Part 11 compliant for electronic records and signatures and includes the following: • (1) Industrial PC / Edge Device to buffer and transmit data to the cloud portal • Connectivity software installed on the industrial PC / edge device to allow it to connect to the PLC • SaniTrend Cloud online portal access • Product features:
SaniTrend Cloud's information on cleaning cycles and system performance; accessed anywhere by anyone from your team
− Store and Forward Capabilities − Cloud Documentation Storage − Live Dashboard Views − Email & SMS (Text) Notifications − Cloud Access to Data (Phone, Tablet, Mobile) − Unlimited Users