DM-0015_SaniTrend® Cloud CR Essentials_IOM_Rev1.0

g. Facility Page – System Properties (Update Property Data)

Note (3)

Note (4)

Note (2)

Notes 1. Property Data is the term for the analog and digital values collected by the system. 2. Tag Name is the primary name of the process value. IMPORTANT NOTE – For CR Essentials, the tag name decides what tab to put the data in for the cycle reports. If the tag name does not contain any of the below text, it will not show up within the cycle report. a. “TEMP” – shows up in the “Temperature” tab b. “COND” or “_pH” or “pH” or “Volume” – shows up in the “Conductivity” tab c. “FLOW” – shows up in the “Flow” tab d. “PRESS” – shows up in the “Pressure” tab e. “LEVEL” – shows up in the “Level” tab f. IMPORTANT NOTE: Contact Sani-Matic if you have other properties not within the above parameters. 3. The units and min/max values for the properties are setup to be per system design at time of shipment (if this information is provided), but they can be modified here as needed. 4. In addition, description text can be added that will show up for any additional details (e.g., tag #) desired to add to the system property. 5. NOTE: Property data cannot be added. When finished with updates, select “Apply Changes” to save.

DM-0015_SaniTrend® Cloud CR Essentials_IOM_Rev1.0

33 of 37

Powered by