TANKO® RF_IOM_Rev0

Mini retractor system TANKO-RF

Designation

TANKO-RF40/-RF50

O-ring material FKM and FFKM Operating pressure, cleaning medium – Liquid medium – Gaseous medium (air or nitrogen)

-15 °C (+5 °F) to +150 °C (+302 °F)

1 – 6 bar (14.5 – 87 psi g) recommended 2-3 bar (43.5 psi g) 1 bar (14.5 psi g), max. 1 min

Volume flow rate (depending on pressure) Process connection [PC]: Media connection [MC]: TANKO-RF40 TANKO-RF50

see Figure 3.3-1 and Figure 3.3-2

see Table 3.1-1: Dimensions and Weights

Clamp DN40, based on DIN 32676 Clamp DN50, based on DIN 32676

Table 3.3-1: Technical Data Consumption Data and Operating Pressure for the Cleaning Process: Consumption data, flow rate depending on pressure

TANKO-RF40

optimum

1,50

6,20

1,25

5,20

1,00

4,20

0,75

3,20

2,20

0,50

1,00

2,00

3,00

4,00

5,00

6,00

Pressure p [bar]

Figure 3.3-1: TANKO-RF40 volume flow rate

3 Design and Function

Operating/Installation instructions 2023/09

31/84

Powered by