TANKO® RF_IOM_Rev0

Mini retractor system TANKO-RF

TANKO-RF50

optimum

4,00

16,60

3,50

14,60

3,00

12,60

2,50

10,60

2,00

8,60

1,50

6,60

1,00

2,00

3,00

4,00

5,00

6,00

Pressure p [bar]

Figure 3.3-2: TANKO-RF50 volume flow rate

The specified values for consumption in the charts are average values and may fluctuate by approx. ± 10% in normal operation. They apply to operation with clear water as the cleaning medium at a temperature of +25 °C (+77 °F). The values may differ if a different cleaning medium or temperature is used. The consumption of cleaning fluid in TANKO-RF40/ -RF50 devices depends on multiple factors, e.g. the pressure of the cleaning fluid and the size of the spray openings. An increase in pressure leads to increased consumption (throughput). The permitted range for the operating pressure of the cleaning medium must be adhered to. The recommended operating pressure of the device is 1.5 - 3 bar (21.7 - 43.5 psi g) for TANKO-RF40 and 2 - 3.5 bar (29 - 50.8 psi g) for TANKO-RF50.

Range of the Cleaning Fluid

TANKO-RF40

0,00 0,10 0,20 0,30 0,40 0,50 0,60 0,70 0,80

1,00

2,00

3,00

4,00

5,00

6,00

Pressure p [bar]

Figure 3.3-3: Range (cleaning radius) TANKO-RF40

32/84

Operating/Installation instructions 2023/09

3 Design and Function

Powered by