TANKO® RF_IOM_Rev0

Mini retractor system TANKO-RF

TANKO-RF50

1,50

1,30

1,10

0,90

0,70

0,50

1,00

2,00

3,00

4,00

5,00

6,00

Pressure p [bar]

Figure 3.3-4: Range (cleaning radius) of TANKO-RF50

3.4 Cleaning Media Due to the wide variety of practical cases of application and use for the cleaning device, it is NOT possible for AWH to recommend specific cleaning media for the owner. The owner bears the sole responsibility for the type of cleaning media, their use and handling. For this reason, AWH can provide the owner with a few reference points and notes (for a device in a container) but only as a precautionary measure, which must be observed and integrated into the owner's hazard assessments. DANGER Risk of explosion as a result of the formation of a potentially explosive atmosphere! There is a risk of death or severe physical injury. • The following items are PROHIBITED for use as cleaning media:

– Fluids which may form a dangerous explosive atmosphere when splashed or sprayed. – Fluids which cause a chemical reaction with the substance to be cleaned that could form a dangerous explosive atmosphere. – Aggressive, flammable or explosive fluids (e.g. acids, thinners, etc.).

WARNING

Danger due to corrosive and aggressive cleaning medium! When handling the cleaning medium, the risk of inhalation, swallowing, contact with the skin, eyes and mucous membranes CANNOT be ruled out. There is a risk of death or severe physical injury. • Adhere to the regulations and specifications on the safety data sheets for the cleaning media (e.g. vapors or hazardous substances).

3 Design and Function

Operating/Installation instructions 2023/09

33/84

Powered by