5.2.2 Installation Position The device is designed for vertical installation, downward suspension or standing upright, as the preferred position. In the event of a different installation position, observe the following: – The running performance may be compromised. – The service life of the bearing elements and springs may be reduced as a result of the increased strain. – Maintenance intervals should be shortened, if necessary (see Section 7.4.1 Maintenance Intervals ).

5.2.3 Installing the Device WARNING Risk of the device falling accidentally!

The device may hit personnel when falling. There is a risk of severe physical injury. • Hold the device firmly when installing/removing it. • There must be nobody beneath the device when installing/removing it.

NOTE Risk of dirt and foreign objects in the device! Functional safety and reliability may be compromised. • During installation, make sure and check that there is no dirt or foreign objects in the device (e.g. small particles, sealing material).

The seal and bracket for the medium connection are not supplied; they are available on request from AWH.

For fastening to the container wall, the AWH container connectors can be used for welding to the container. The advantage is, via the funnel-shaped connection: Different container or pipe diameters can thus be covered. The container connector is designed to seal with the container wall via the special sealing contour with the O-ring. 5.2.3.1 Welding of the Container Connector The seal and bracket for the medium connection and the clamp process connection are not supplied. They are available on request from AWH.

If the internal diameter of the container (2 x R) is known, the container connector can be ordered with a corresponding radius at an additional cost, or it can be modified by the customer. For more information, please consult AWH.