TANKO® RF_IOM_Rev0

Mini retractor system TANKO-RF

A

B

C

E

D

S

O

F

G

R

D

Figure 5.2-5: Mounting TANKO-RF with Clamp PC on Clamp Container Connector

R Container / pipe (operator side) S Container connector (please order separately, see Table 3.1-2: Container connector ) C Seal (not included in the scope of delivery) D Heavy duty clamp (not included in the scope of delivery) E TANKO-RF… C-C F Seal (not included in the scope of delivery) G Media supply (owner side) O O-ring (is also supplied pre-assembled) 3. Slide the seal for the clamp connection (not included in the scope of delivery) on to the housing of the device up to the clamp process connection (A). • Ensure that the O-ring is correctly seated at the bottom edge of the housing. Push the device into the container connector on the container as far as it will go and connect it with the heavy duty clamp (not included in the scope of delivery). 4. Install the cleaning medium supply (standard: clamp in accordance with DIN32676) on the media connection (B) with suitable seal and clamp. The seal and clamp are not included in the scope of delivery

5.2.3.3 Installation of Threaded Connection PC

A - prozess connection (PC) thread

B

B - media connection (MC) clamp

A

Figure 5.2-6: Installation of threaded connection

5 Installation

Operating/Installation instructions 2023/09

45/84

Powered by