TANKO® RF_IOM_Rev0

Mini retractor system TANKO-RF

1. Take the container connector out of the packaging and perform a visual inspection for damage. Protect that the O-ring that seals the housing of the TANKO-RF from the container connector from damage. 2. Check the sealing surface in the container connector as well as on the clamp connection of the media supply (B, fig. 5.2-6) and the thread (A, fig. 5.2-6) for contamination. Keep the O-ring, O-ring groove and interior surface in the container connector clean. Place the O-ring correctly in the O-ring groove of the housing, if not already pre-assembled. The contact surfaces of the connection between container connector (A, fig. 5.2-4) and housing and on the media connection (A, fig. 5.2-4) must be kept clean.

A

B

O

S

F

R

E

G

D

Figure 5.2-7: Installation of TANKO-RF with Thread PC on Thread Container Connector

R Container / pipe (operator side) S Container connector (please order separately, see Table 3.1-2: Container connector) D Heavy duty clamp (not included in the scope of delivery) E TANKO-RF… G-C F Seal (not included in the scope of delivery) G Media supply (owner side) O O-ring (is also supplied pre-assembled) 3. Screw the device with the external thread into the container connector piece on the connector. NOTE There is a risk of damage to the thread if the tightening torque applied to the threaded device connection and the container connector is excessive! • Observe the tightening torque, see Table 7.5-2 and Table 7.5-6 . 4. Install the cleaning medium supply (standard: clamp in accordance with DIN32676) on the media connection (B) with suitable seal and clamp. The seal and clamp are not included in the scope of delivery.

46/84

Operating/Installation instructions 2023/09

5 Installation

Powered by