TANKO® RF_IOM_Rev0

Mini retractor system TANKO-RF

7.3.1 Removing the Device

B A

C

D

Figure 7.3-1: Overview of Assembly Units A Process connection [PC] B

Media connection [MC] (cleaning agent feed)

C D

Housing

Spray head

WARNING Risk of the device falling accidentally! The device may hit personnel when falling. There is a risk of severe physical injury. • Hold the device firmly when installing/removing it. • There must be nobody beneath the device when installing/removing it.

Interface B The supply line for the cleaning medium must be disconnected at the media connection [MC]. The media connection [MC] must be sealed with a screw cap. 1. Check to make sure that the media supply is interrupted (see Section 7.2 Switch-off Procedure) . 2. Undo the screw connection on the heavy duty clamp.

3. Remove the heavy duty clamp. 4. Keep the seal in a safe place.

Interface A Clamp Process Connection 1. Release the heavy duty clamp at the process connection and set it to one side. 2. Remove the device from the clamps on the container. 3. Store the seal and O-ring in a safe place. 4. If necessary, close the clamps on the container.

58/84

Operating/Installation instructions 2023/09

7 Maintenance