TANKO® RF_IOM_Rev0

Mini retractor system TANKO-RF

Thread Process Connection 1. Loosen the device using a wrench with the appropriate width across flats, AF36 for RF40, AF50 for RF50. 2. Remove the device from the threaded connector on the container. 3. Keep the seal in a safe place. 4. If necessary, close the container connector on the container.

7.4 Maintenance To ensure trouble-free operation, high operational safety and long service life of the cleaning device, it is essential to have it cleaned and maintained at regular intervals.

We recommend that you document the maintenance work in a report.

The safety instructions in Section 7.1 Safety Instructions for Maintenance must be adhered to when carrying out cleaning, maintenance and repair work.

NOTE

Danger due to leaks at the connections! The sealing elements of the process connection [PC] and media connection [MC] are manufactured in accordance with the technical requirements for sealing surfaces. Incorrect operation of the device can cause damage to the sealing elements (e.g. scratches and tears). This can result in the penetration or escape of media at the connections. This can result in leaks and the corresponding dangers. • Protect sealing elements from damage and contamination during transport, storage, assembly and cleaning!

• Check them regularly for impermeability • Replace the seal in the event of leaks • If these measures are not successful, contact the manufacturer

7 Maintenance

Operating/Installation instructions 2023/09

59/84

Powered by