TANKO® RF_IOM_Rev0

Mini retractor system TANKO-RF

Overview of Maintenance Points

A Screw connection housing / cover B Screw connection axle cover / axle center section C Pressure spring for closing the device D Wire locking pin for connecting plate axle and center hole in spray head E Plain bearing spray head F Spray slots, spray head G Spray holes in plate axle H O-ring plate seal J O-ring, sealing of container connector K Clamp connection media connection [MC] L Clamp/screw connection process connection [PC]

A

B C

K

D G F

L

E

H

J

Figure 7.4-1: Maintenance Points

The tightening torques required for the screw connections for maintenance are listed in Table 7.5-1 .

The item numbers shown in parentheses refer to Figure 7.5-1: Internal design.

62/84

Operating/Installation instructions 2023/09