SANICAB® PC CABINET WASHER
NOTE • Sani-Matic standard is to design steam heating applications for 50 psi steam. For installations where the plant-supplied steam is more than 50 psi, a pressure reducing valve (PRV) may be required to be installed (by others).
TABLE 10: STEAM HEAT EXCHANGER DATA
Skid Dimensions
Approx. Heat-up Time 68 °F to 140 °F (min)
Connection Size / Type (Condensate Return)
Connection Size / Type (Steam Supply)
Chamber Model
Load (lbs/hr)
W" D" H" PC335 20 50 70 PC365 20 50 70
3 6
2" FLG 2" FLG
1.5" FLG 966 1.5" FLG 966
The No Recirculated Heating option removes the electric heater assembly in the standard system’s recirculation piping. This option is intended for applications where the supply water temperature is adequate for washing cycles. 10.6 Supply Pressure Monitoring The Pressure Transmitter option replaces the pressure gauge in the recirculation system downstream of the angle-line strainer with a diaphragm type pressure transmitter with local indication. The pressure transmitter has a 0-100 psi range and 4-20 mA output. This option adds system monitoring and alarming capabilities for the recirculation system pressure. 10.7 Supply Flow Monitoring The Flow Switch option adds an insertion probe style flow switch to the recirculation system. The flow switch has a discrete output. This option adds system monitoring and alarming capabilities for the recirculation system flow, based on the discrete output. The Flow Meter option adds a turbine flowmeter with local indication to the recirculation system. The flow meter has a 25-250 GPM range and 4-20 mA output. This option adds system monitoring and alarming capabilities for the recirculation system flow. 10.8 Chemical Control The Wash & Rinse Conductivity Control option replaces the standard wash conductivity sensor, which can read between 200µS/ cm and 1,000mS/cm with a more sensitive sensor with dual ranges that can read between 1µS/cm to 200mS/cm. The two range options are as follows: • Wash Conductivity – used for controlling chemical wash steps • 0.2 ms/cm – 200 ms/cm Range • Rinse Conductivity – used for ensuring final rinse conditions (low conductivity) are met • 1 µS/cm – 50 mS/cm Range 10.9 Reporting These options can replace the standard No Reporting option for recording the critical cleaning cycle parameters of the SaniCab PC: • SaniTrend® Local CR • SaniTrend® Local Data+
• SaniTrend® Cloud CR Essentials • SaniTrend® Cloud CR Insights • SaniTrend® Cloud CR Insights+
The SaniTrend® Local CR reporting option provides a means of storing, retrieving, and printing the SaniCab PC cleaning cycle data with a desktop PC.
Sample SaniTrend Local CR Printout