10. Product Options
10.1 Tank Insulation The Insulated Tank option adds an insulated sidewall to the CIP tank for heat conservation and personnel protection The insulation is chloride free with 304ss sheathing 10.2 Skid Mobility Selecting the Stationary option removes the casters and push handle and adds four (4) adjustable ball feet making the system suitable for stationary placement in the facility 10.3 Recirculated Heating There are three (3) available options for heating the CIP solution: • In-Tank Steam Sparger • Heat Exchanger – Steam • Electric Heater – 30 kW With the In-Tank Steam Sparger option, steam is directly injected into the wash solution in the tank to elevate its temperature The RTD is relocated from the supply manifold to the tank sidewall The following are specifications for this option: • Steam supply manifold − One (1) 1" Strainer with manual ball valve for blow down − One (1) 1" Automated ball valve for on/off steam control − One (1) Steam mixer located in the tank − Material: Stainless steel pipe − Welding : Welds are performed manually per AWS D181/D181M standards (latest edition) Pipe 2” and smaller will be
socket welded Pipe 25" and larger will be butt welded − Weld finish: As welded ID / weld color removed OD − Connections: NPT or 150 lb flange
− Flange gaskets: Non-asbestos ring type − Valves: Ball type with stainless steel body • Duty: Heat 135 gallons of wash solution from 68 °F to 140 °F in 7 minutes • Steam Supply: 760 lb/hr @ 50 psi
With the Heat Exchanger – Steam option, a shell & tube heat exchanger provides indirect heating of the wash solutions The heat exchanger will be located in the discharge of the supply pump The following are specifications for this option: • One (1) Shell & tube heat exchanger − Duty: Heat 110 gallons of wash solution 17°F per pass − Steam Supply: 1,065 lb/hr @ 50 psi
− Single tubesheet − Insulation: None − Design: ASME rated for 150 psi / full vacuum − Material : 316Lss wetted surfaces − Interior finish: 32 µ-in Ra with welds ground smooth − Exterior finish: Manufacturer’s standard • One (1) Vacuum breaker (brass) • Steam supply manifold
− One (1) 2" Strainer with manual ball valve for blow down − One (1) Pressure gauge with manual ball valve for isolation − One (1) 125" Control ball valve with V-notch ball and electro-pneumatic positioner − One (1) Pressure relief valve with its discharge piped to the floor • Condensate return manifold − One (1) 05” Manual ball valve to drain the shell of the heat exchanger − One (1) 15” Float and thermostatic steam trap − Weld finish: As welded ID / coated with high temperature paint OD − Connections: NPT or 150 lb flange
− Flange gaskets: Non-asbestos ring type − Valves: Ball type with carbon steel body