TD-0006_CIP Mini_Technical Datasheet_Rev2.0

10.12 CIP Supply Strainer The Angle-Line Strainer option adds a strainer which removes solids from the wash solutions, protecting spray devices and other equipment from debris, and is installed in the discharge of the supply pump The following are specifications for this option: • One (1) 2" TC x 2075" long Angle-Line strainer with 0015" wedgewire element and standard seal kit 10.13 CIP Supply Air Blow The Air Blow option helps reduce the time required to evacuate water from the process piping during drain steps through use of compressed air blowing through the process lines The following are specifications for this option:

Angle-Line Strainer

• One (1) 2" Y-Ball check valve located in the discharge of the supply pump • One (1) Air blow inlet with 05 micron filter disc mounted to the check valve • One (1) 05" Solenoid valve and regulator, located in the control panel, for control of the air blow • The instrument air requirement will increase by 25 cfm

10.14 Local Chemical Addition There are four (4) options for adding local chemical addition to the skid: • Local Chemical Pump Assembly • Local Chemical Pump Assembly & (1) Chemical Reservoir with Low-Level Switch • Local Chemical Pump Assemblies • Local Chemical Pump Assemblies & (2) Chemical Reservoirs with Low-Level Switches These options add the below items to the skid as noted If only selecting the Local Chemical Pump Assemblies, they can be used with nearby chemical drums – for a complete solution, add the chemical reservoirs Local Chemical Pump Assembly - the chemical pump assembly doses the cleaning chemicals and/or sanitizer from a storage drum to the injection point on the CIP system The concentrations are controlled to a time based setpoint value or to a conductivity setpoint value if the Conductivity Monitoring/Control option is chosen The chemical pump assembly(s) are mounted to the CIP frame The following are specifications for this option: • One (1) Suction lance with foot valve for placement into a drum (by others) • One (1) Air operated diaphragm pump − Duty: 3 gpm @ 45 psi − Polypropylene body with Teflon diaphragms − (1) 025" Solenoid valve (24V DC) with filter/regulator for control of the pump The pneumatic components and piping are made of brass • One (1) Manual bleed valve to aid in the priming the pump

• One (1) 025" Check valve to prevent the siphoning of the cleaning chemicals • Thirty (30) feet of 05" Polyethylene tubing for the pump’s suction and discharge

Chemical Reservoir with Low-Level Switches - the reservoir provide an on-skid location to store chemical for use in the cleaning cycle Quick disconnects make the reservoir easy to remove for filling A level switch is integral to the assembly, providing a low-level alarm The following are specifications for this option: • (1) Removable chemical reservoir

− Volume: 5 gallons − Access: Hand hole − Vent: Closeable − Design: Atmospheric − Material: Polypropylene − Suction lance with foot valve − Quick disconnect couplings for ease of removal • One (1) tray to hold the chemical reservoir • One (1) non-contacting capacitive type with on/off output

10.15 Controls The Allen-Bradley CompactLogix 5380 Controller option replaces the standard Allen-Bradley® CompactLogix™ 5370 Controller offering with the upgraded 5380 Controller series processor The corresponding I/O modules are also upgraded

sanimatic.com 16