TD-0006_CIP Mini_Technical Datasheet_Rev5.0

MODEL NUMBER KEY

EXAMPLE MODEL #: CIPM110055-1APPU-MN0AT-00000000-0000C

1 2 3 4 5 6 7 8 9 10 1112131415 1617181920

21 22 23 24 25 26 27 28 29 30 31 32 C

MODEL & FLOW RATE CIPM110 CIP Mini - 110 gpm

CIP SUPPLY PRESSURE MONITORING 0 No Supply Pressure Monitoring (Standard) G Supply Pressure Gauge T Supply Pressure Transmitter CHEMICAL MONITORING & CONTROL 0 No Chemical Monitoring & Control (Standard)

1–7

23

CIP PRESSURE 055 55 psig

8-10

TANKS 1

11

24

One Tank

1 2

Wash Conductivity (CIP Supply) Monitoring

TANK SIZE A

12

Wash & Rinse Conductivity (CIP Supply & Return) Monitoring

135 gal Nominal Volume

13- 14

CIP RETURN FLOW MONITORING 0

25

TANK HEAD TYPE

No Return Flow Monitoring (Standard)

PP

Panned & Radiused Tank Heads

1

Return Flow Switch

TANK INSULATION U

15

CIP SUPPLY STRAINER 0

26

Uninsulated Tank (Standard)

No Strainer (Standard) Angle-Line Strainer

I

Insulated Tank

A

SKID MOBILITY M

16

CIP SUPPLY AIR BLOW 0

27

Mobile (Standard)

No Air Blow (Standard)

S

Stationary

A

Air Blow

HEATING N

17

LOCAL CHEMICAL ADDITION 0

28

No Heating Method (Standard)

No Local Chemical Pump Assemblies (Standard)

S X E

In-Tank Steam Sparger Heat Exchanger - Steam Electric Heater - 30 kW

A B C D

(1) Local Chemical Pump Assembly

(1) Local Chemical Pump Assembly & (1) Chemical Reservoir with Low-Level Switch

(2) Local Chemical Pump Assemblies

RECIRCULATION MANIFOLD 0

18

(2) Local Chemical Pump Assemblies & (2) Chemical Reservoirs with Low-Level Switches

No Recirculation Manifold (Standard)

CONTROLS 1 HMI DISPLAY 0

29

R

Recirculation Manifold

Allen-Bradley CompactLogix 5380 Controller (Standard)

CIP TANK WATER INLET A

19

30

Anti-Siphon Inlet (Standard)

Allen-Bradley PanelView™ Plus 7 - 7" Operator Terminal (Standard)

S

Static Spray Ball Inlet - With Gasketed Manway

1

Allen-Bradley PanelView Plus 7 - 10" Operator Terminal

PUMP MOTOR TYPE T

20

CONDUIT 0

31

TEFC (Standard) Washdown Duty

PVC Conduit (Standard) Stainless Steel Conduit

W

1

S

Stainless Steel Washdown Duty

REPORTING 0

32

CIP SUPPLY FLOW & PRESSURE CONTROL 0 No Supply Pump VFD Control (Standard) V Supply Pump VFD Control

21

No Reporting (Standard)

1 2 F

1-Pen Chart Recorder, Anderson AJ-300 Series 2-Pen Chart Recorder, Anderson AJ-300 Series 2-Pen Chart Recorder, Anderson AV-9000 Series 3-Pen Chart Recorder, Anderson AV-9000 Series 4-Pen Chart Recorder, Anderson AV-9000 Series

CIP SUPPLY FLOW MONITORING 0

22

No Supply Flow Monitoring (Standard)

G H

M

Supply Flow Meter

L E

SaniTrend® Local CR

SaniTrend® Cloud CR Essentials SaniTrend® Cloud CR Insights

C

2

CIP MINI TECHNICAL DATASHEET

Powered by