7.4 HEATING SYSTEM No heating method is provided. The system will wash the target equipment using water at the temperature supplied.
7.5 CONTROL SYSTEM 7.5.1 Control Panel
This control panel houses the components used to control the system and is skid mounted. • One (1) UL Listed enclosure, NEMA 4X, 304ss construction with painted carbon steel back plate • One (1) Allen-Bradley Bulletin 5069 CompactLogix 5380 with associated digital and analog outputs • One (1) Ethernet switch, 5-port unmanaged • One (1) 24V DC, 10 Amp power supply • Air solenoid valves (as required) • One (1) Low air pressure alarm switch • One (1) Instrument air filter • One (1) Instrument air pressure regulator with gauge • One (1) Disconnect switch rated for 30 Amps • One (1) 7.5 HP motor starter (for CIP Supply pump) • One (1) Transformer to convert the incoming 3-phase power to other needed voltages • Twenty (20) ft. of SO cord power cord (plug not included) 7.5.2 Operator Interface Operator interfaces include the HMI and other components installed on the control panel. • One (1) Allen-Bradley PanelView Plus 7 from Rockwell Automation - 7" color touchscreen, Operator Terminal (HMI) • One (1) Illuminated emergency stop switch
• One (1) Illuminated reset button • One (1) 120V AC GFCI Receptacle • One (1) RJ45-F Ethernet Passthrough
8 EQUIPMENT OPERATION 8.1 SYSTEM OPERATING CONDITIONS • Maximum System Operating Temperature: 200 °F • Maximum System Operating Pressure: 60 psi NOTE: • Achievable operating temperatures are dependent on system options and utility conditions.