TD-0009_Digital Process Recorder (DPR)_TD_Rev3.0

DIGITAL PROCESS RECORDER (DPR)

INSTALLATION & OPERATING REQUIREMENTS

Control Panel Requirements • Installation of DPR Control Panel (NEMA 4X, 16” W x 20” H x 8” D) on frame or wall • 120V AC / 6 Amp Power • Broadband Internet Access (Ethernet/RJ45 or WiFi - WiFi requires optional WiFi access module) • DPR Reports Requires Hard Wired Running Signal or Communication (Ethernet/RJ45) to Plant Equipment/Network for Running Signal* *NOTE: Equipment communicating to is required to be an Allen-Bradley CompactLogix™ or ControlLogix ® PLC Processor Internet Browser (for SaniTrend Cloud online portal access) - Chrome (recommended) with Screen Size - 1920 x 1080 (recommended)

DIGITAL PROCESS RECORDER (DPR) HARDWARE & SOFTWARE SPECIFICATIONS

COMPONENT

MANUFACTURER

MODEL

Industrial PC/Edge Device

Allen-Bradley

Versaview 6300

SaniTrend Cloud Online Portal

PTC

ThingWorx SaaS

PLC

Allen-Bradley

Micro 820

HMI

Allen-Bradley

MIcro 800 LCD

WIFI CONNECTION PACKAGE (OPTIONAL) HARDWARE SPECIFICATIONS

COMPONENT

MANUFACTURER

MODEL

Industrial Hotspot

Anybus

Wireless Bolt

Industrial Switch

Allen-Bradley

Bulletin 1783 Stratix 2000

6 | DIGITAL PROCESS RECORDER (DPR)