4. Alarm reset button 5. Schematics and documentation as required by UL standards

Included Connections, Sensors, and Valves • Analog Input M12 Cable Connections o Temperature Sensor

• Digital Input M12 Cable Connections o Door Proximity Sensor (Interlock) o Sump Level Sensor The Door Proximity Sensor is an Interlock on the CyClean. If additional Interlock functionality is desired, it is the responsibility of the end user to wire their device into this connection, however, this may void the warranty.

• Digital Output M12 Cable Connections o Fill Valve o Drain Valve o Exhaust Fan (14AWG Connector)

Optional Connections Additional connections are available on the CyClean 35. These connections may be made by connecting to pre-existing connectors on the bottom side of the electrical enclosure, but some connections may require additional connections to be made. See section 7) ACCESSORIES for more information. Accessing the PLC The CyClean is a standard machine with no available factory customizations. As a result, the programming in the CyClean is standard and the same for each unit manufactured. While newer software versions may exist, each iteration is intended to be fully reverse-compatible. Because of this, the coding will be locked, and access will not be allowed for the end user. If additional features are required, discuss these needs with your local CleanWorx representative.

Limited access is available if the end user wishes to interact with the built-in tags or with the FactoryTalk Historian SE. Details for connection are listed below:

Connection via FactoryTalk Historian SE Requirements: