4) INSTALLATION AND START-UP 4.1) Location and Preparation When planning the location of the CleanWorx CyClean, the following should be kept in mind:
1. The machine will need to be installed on a level surface. Installation on sloped floors is not recommended.
2. The machine will need to be within proximity of the following utilities to operate. See section 2.2) Utility Connections for the recommended requirements of the CyClean.
a. Hot water supply b. Drain connection c. Electrical supply d. Vent connection
3. The process/equipment flow throughout the plant should be taken into consideration. Ideally, the CyClean should be located in a dedicated space, separate from other processing areas, where dirty parts can be safely loaded into the CyClean.
4. Adequate clearance must be provided so that the cylinder door may be opened, and a Sanitation Cart can be wheeled into and out of the chamber.
5. Adequate clearance for servicing items like the electrical controls box, heater, and pump should be considered if these items must be serviced or removed. For example, if the pump is located next to a wall, sufficient space should be allowed to permit easy servicing. A three (3) foot clearance is recommended, but plant or local guidelines may vary. 6. If chemicals are used, they must be non-foaming and must not contain any chlorine. Be sure to understand the recommended usage, specifically the chemical concentration and any temperature limits prior to modifying any recipes. See section 5.4) Configuring a CyClean Wash Recipe for more information.