DM-0018_CleanWorx™ CyClean™ 35_IOM_Rev1.2

4.2) Leveling Once the CyClean is placed in its final place, the height may need to be adjusted and/or the CyClean may need to be leveled. First, confirm the CyClean is at the correct height. Measure from the floor to the front lip as shown below, then use a Sanitation Cart to ensure there is no interference. Repeat and adjust as needed. Once confirmed that the CyClean is at the correct height, the CyClean will need to be leveled. Measure at several locations around the CyClean the distance labeled below as “confirm level”. This distance should be within ±1/8 at any given point. Adjust leveling feet as needed. Mounting holes are included as part of the leveling feet. It is at the discretion of the end user whether they are to be used, and if used, it is the end user's responsibility to determine appropriate mounting hardware.

After the CyClean has been leveled at the correct height, the Cyclonejet 360° Spray Arm and pump and motor assembly can be reinstalled. See section

17