DM-0018_CleanWorx™ CyClean™ 35_IOM_Rev1.2

3.1) Safely Lifting and Transporting . Once the Cyclonejet 360° Spray Arm has been reinstalled, ensure the Sanitation Cart does not make contact with the Wash Cylinder or the CycloneJet 360° Spray Arm. Mounting holes are included on the motor mounting plate. It is at the discretion of the end user whether they are to be used, and if used, it is the end user's responsibility to determine appropriate mounting hardware. 4.3) Initial Start-Up Pre-Check Prior to initial start-up, check each utility supply to verify complete and secure connections are made and that the connections meet the requirements listed in section 2.2) Utility Connections . Common issues include, but are not limited to: • The water fill valve is either not connected, the water supply line is restricted, or the water supply line is not sized appropriately. • The drain port valve is not connected, the drain line is restricted, or the drain line is not sized appropriately. • The exhaust port is not connected, the exhaust line is restricted, or the exhaust line is not sized appropriately. • If used, chemical line(s) are not connected to the chemical port(s), the proper electrical connections are not made, or the appropriate accessories have not been enabled. • Fuses, overload protection and circuit breakers are not installed or properly sized. • Electrical service is either not connected to the control cabinet or is not the proper voltage defined in section 2.2) Utility Connections .

Using the proper tools, ensure the incoming power to the panel is the correct voltage at the disconnect prior to turning on the main disconnect.

At this point, the main disconnect on the control panel can be switched to “ON”. The last step is to check the rotation of the supply pump. Follow the instructions below to ensure that the pump is spinning in the correct direction. Further details about the HMI can be found in section 5.1) Typical Operation Instructions .

1. Hazardous voltage exists; disconnect power to the control panel and pump motor before servicing the equipment.

CleanWorx ™ CyClean ™ 35 IOM

Powered by