DM-0018_CleanWorx™ CyClean™ 35_IOM_Rev1.3

4.4) Start-up Procedure

At this point, the main disconnect on the control panel can be switched to “ON”. The last step is to check the rotation of the supply pump. Follow the instructions below to ensure that the pump is spinning in the correct direction. Further details about the HMI can be found in section 5.1) Typical Operating Instructions .

1. Hazardous voltage exists; disconnect power to the control panel and pump motor before servicing the equipment.

2. Announce the lock-out to other personnel around the equipment.

Step 1: When turning the CyClean power on, the warning screen (shown below) will appear to notify that there has been a power loss to the PLC. See section 9.1) Error Code Descriptions for more information. To clear this screen: 1. Ensure the E-Stop is not engaged. 2. The reset button should be illuminated. Press the reset button, the light should turn off. 3. Press the “approve” checkmark on the HMI touchscreen or the (F2) button.

1. E-Stop

3. Approve

2. Reset Button

CleanWorx ™ CyClean ™ 35 IOM