Step
Setpoint
Description
Time (sec) that this Step runs assuming the criteria below are met. The runtime timer will not count until all criteria is met. Minimum temperature (°F) requirement for this Step runtime to count. Time (sec) that this Step runs assuming the criteria below are met. The runtime timer will not count until all criteria is met. Minimum temperature (°F) requirement for this Step runtime to count. Minimum conductivity (mS/cm) requirement for this cycle step to run. Note: Requires conductivity sensor. Time (sec) for chemical addition. Note: This Operation happens with or without a conductivity sensor installed. Time (sec) that this Step runs assuming the criteria below are met. The runtime timer will not count until all criteria is met. Minimum temperature (°F) requirement for this Step runtime to count. Time (sec) that this Step runs assuming the criteria below are met. The runtime timer will not count until all criteria is met. Minimum temperature (°F) requirement for this Step runtime to count.
Pre-Rinse Runtime
Pre-Rinse Temperature
Pre-Rinse
Wash Runtime
Wash Temperature
Wash Chemical Conductivity
Wash
Wash Chemical Add Time
Rinse Runtime
Rinse Temperature
Rinse
Sanitize Runtime
Sanitize Temperature Sanitizer Add Time Exhaust Time
Sanitizer
Time (sec) for sanitizer addition.
Exhaust
Time (sec) the exhaust fan will run.
Any values set to 0 will be skipped in the Wash Recipe . i.e. if the pre-rinse time is set to 0, the pre-rinse step will be skipped. Likewise, if the wash temperature is set to 0, the Step will not have a requirement to reach a specific temperature. Every Setpoint is hard coded to either not go below or above a specific predetermined value. If entering a value higher or lower than the predetermined value, the predetermined value will be used instead. i.e. if a wash temperature of 9999°F is entered, the CyClean will default to the predetermined maximum wash temperature instead.
45
Powered by FlippingBook